Predictive HVAC Monitoring

LoggerFlex HVAC monitoring uses EDGE and BLOCK loggers to track supply and return temperatures with probes from -55 °C to +125 °C (-67 °F to +257 °F) and compressor or fan current with a 0.2 to 30 A CT clamp, sending phone call, SMS and email alarms before a fault becomes a callback.

Detect early signs of equipment failure, reduce downtime, and extend asset life through data-driven insight.

HVAC Monitoring

The IoT soul inside equipment makers worldwide

50,000+
devices deployed in the field
2 US patents
US 11,455,877 B2 and US 12,761,648 B2 low-power datalogger technology
NIST · FDA · NSF · HACCP
NIST-traceable calibration, FDA 21 CFR Part 11, HACCP records, and EDGE loggers designed in compliance with NSF/ANSI 456
EDGE & BLOCK built in Canada
Designed in Canada · Servers only in Canada
WiFi + global eSIM
No gateway. Built-in cellular across 170+ countries

Why LoggerFlex?

IoT for Buildings designed for rapid deployment, unbreakable reliability, and actionable insight.

No Gateway Required

Devices connect directly to WiFi or cellular networks for fast and easy installation.

Instant Alerts

Get instant phone calls, text messages, and emails for leaks, pressure drops, or temperature spikes.

One Platform

Manage all client sites, devices, alarms, reports, and users from a single simple app.

Actionable Insight

Detect anomalies and equipment failures early with predictive maintenance and automated analytics.

Share Securely

Share live system status and reports with your technicians and facility managers securely.

Remote Access

Monitor fields, greenhouses, barns, and storage facilities from any device worldwide.

Scales Instantly

Grow from monitoring a single fridge to a full building automation system without changes.

Predictive Maintenance

Prevent expensive failures by detecting early signs of trouble with simple, cost-effective sensors.

Featured Hardware

Industrial-grade sensors for climate control and mechanical systems.

Explore All
BLOCK Current

BLOCK Current

Electrical current & temperature for motors, compressors, and HVAC. Identify abnormal load patterns and energy waste.

  • 0.1 to 30 A (non-invasive)
  • Predictive motor health
  • Short cycling & belt breakage detection
Current Sensor
EDGE Thermo

EDGE Thermo

Ambient temperature, RH, and mold index tracking for predictive facility maintenance.

HVAC Node
Modbus Gateway

Modbus Gateway

Bridge any standard 4-20mA or Modbus sensor directly to the LF Cloud.

Cellular Water Meter

Cellular Water Meter

Track building water use with a daily report and leak alarms, over built-in 4G with no WiFi or gateway.

View Specs
BLOCK Differential

BLOCK Differential

Being retired

Differential air pressure for cleanrooms, ventilation verification, and HEPA filter status.

BLOCK Pulse

BLOCK Pulse

Being retired

Utility sub-metering for gas, water & electricity. Cumulative pulse counting with anomaly detection and freeze risk alerts.

BLOCK Pressure

BLOCK Pressure (Fluid)

Fluid pressure & temperature monitoring for HVAC loops, plumbing, and tanks. Detect leaks and verify pump head pressure.

Comprehensive Applications

From predictive motor health to critical cleanroom monitoring, discover how LoggerFlex monitors every vital element of your HVAC facility.

Motor & Compressor Protection

  • Monitor for high current draw to prevent burnout in compressors and motors.
  • Track gradual increases in power consumption to identify wearing bearings before failure.
  • Identify rapid on/off cycling that damages equipment and increases energy costs.
  • Detect sudden drops in current that indicate broken belts or coupling failures.

Pressure & Flow Monitoring

  • Verify pump discharge pressure to ensure proper flow rates and catch impeller wear.
  • Monitor critical pressure in refrigerant loops, fire extinguishers, and sprinkler lines.
  • Notify when pressure spikes due to dirty condenser coils or fan failures.
  • Detect pressure changes indicating clogged liquid filters or measure hydrostatic pressure for tank levels.

Cleanroom & Isolation Safety

  • Ensure critical environments like hospital isolation rooms maintain correct negative/positive pressure.
  • Monitor airflow resistance across HEPA filters to detect clogging early.
  • Verify that fans and blowers are actually moving air, not just spinning.
  • Receive instant alarms if containment conditions are breached.

Ventilation & Air Quality

  • Detect dangerous CO₂ buildup instantly to prevent occupational hazards.
  • Monitor CO₂ levels to optimize smart ventilation control and balance energy use.
  • Verify air exchange efficiency using real CO₂ load data.
  • Identify harmful exhaust gas or CO₂ intrusion from heaters or generators.

Water & Facilities Tracking

  • Measure and analyze water consumption to reduce waste and operating costs.
  • Identify hidden leaks and unusual water consumption patterns.
  • Monitor ambient temperature to reduce pipe freezing and rupture risk.

Third-Party Integration

  • Connect any 4-20mA or Modbus sensor directly to the cloud.
  • Power external sensors and read their data using our battery-powered wireless bridge.
  • Unify specialized environmental safety sensors (Radon, NO2, Ozone) into a single platform.

Trend-Based Predictive Maintenance

Trend drift detection compares sensor patterns against their own history to flag equipment heading toward failure. Industry example: up to 75% less downtime and 35% longer equipment life (not a measured LoggerFlex result).

Trend Analysis

Trend drift detection compares scheduled data with each unit's own history to detect gradual degradation.

Drift Detection

Monitors subtle shifts in current draw, refrigerant pressure drift (pressure sensor on the line) and temperature; bearing vibration comes with the upcoming EDGE Multi.

Early Warning Alerts

Actionable alerts with context — not just threshold alarms.

Predictive Maintenance Dashboard

75%*

Fewer Breakdowns

25%*

Lower Energy Costs

35%*

Longer Equipment Life

3 wk*

Early Warning Lead

*Industry examples, not measured LoggerFlex results.

Recommended Catalogs

Frequently asked questions

Can LoggerFlex sensors integrate with our existing BMS or building automation system?

Yes. Our Modbus Gateway bridges any standard Modbus RTU/TCP equipment into the LoggerFlex Cloud, and EDGE devices push data over WiFi or cellular LTE, so you can layer automated monitoring with instant alarms on top of an existing BMS without ripping out hardware.

How does predictive maintenance reduce HVAC downtime?

Continuous current, temperature and pressure logging lets trend drift detection flag gradual change and abnormal readings before a unit fails. Maintenance teams receive early alerts and can schedule service proactively instead of reacting to emergency breakdowns.

What parameters can I monitor for heat pumps and rooftop units?

You can monitor electrical current draw, supply and return air temperature, relative humidity, differential air pressure across filters and coils, fluid pressure, and water consumption — all from a single cloud dashboard with configurable alarm thresholds.

Are LoggerFlex HVAC sensors suitable for OEM and white-label integration?

Absolutely. LoggerFlex is a prime OEM partner for heat-pump and HVAC manufacturers, offering white-label hardware, custom firmware, and a brandable cloud platform so you can ship connected monitoring under your own name.

OEM / custom version available

Make your product smart — without building an IoT team.

If you build equipment, we put the IoT soul inside it — hardware, firmware, global connectivity, cloud, alarms and compliance, shipped as a finished product under your brand.

Guides