Skip to content

Understanding the Mold Index

A predictive, scientific approach to identifying environments favorable to mold growth—before visible damage occurs.

LoggerFlex EDGE Essential temperature and humidity datalogger
MoldMold Index · 4%

Built into every EDGE Series device

Mold Index calculation isn't an add-on — it's a standard, built-in function in every EDGE Series device. Each logger continuously scores its own temperature and humidity against the growth model, so your risk reading is always current, with no extra hardware or setup.

  • Badge on the device. The device calculates the 0–100% Mold Index itself, and the LoggerFlex app shows the current value as a mold badge on that device's card.
  • Percentage on hover. Hover over the icon and it reveals the exact Mold Index percentage, so you can see how far conditions have drifted at a glance.
  • Warnings by email and SMS. On corrected firmware (October 2026) you get one message for each level the index crosses: 5%, 25%, 50%, 75% and 100%. At room temperature the index often jumps straight to 100%, so only that message arrives. Older firmware sends a single warning at 83%; a device gets the fix when it is updated.
  • Back-to-normal message. When conditions dry out, one message tells you the index is back under 1% (older firmware: back under 17%).
  • Its own switch. Mold Index Notification is a separate switch in the device settings: turn it off to stop mold messages from that device without affecting any other alarm.

Mold Index moves slowly by design. At room temperature it can stay at 0% through days or weeks of high humidity and then climb to 100% within one or two readings; near freezing it climbs over hours. It falls slowly in dry conditions, about 10 days from 100% to 83%. A high value means conditions have favoured mold, not that mold is present. LF Cloud keeps the current value only; there is no Mold Index history chart.

Mold index visualization

The Science Behind It

The LoggerFlex Mold Index is rooted in established mathematical models of mold growth, originally developed for the most vulnerable building materials (like untreated wood).

In scientific literature, mold risk is often calculated on a technical 0 to 6 scale. While accurate for researchers, this scale can be unintuitive for facility managers and property owners.

To make this data immediately actionable, we map the scientific 0-6 scale onto a simple 0% to 100% gauge.

How the Viitanen mold model works

The Mold Index follows the mold growth model developed at VTT Technical Research Centre of Finland by Hannu Viitanen and colleagues. They kept pine and spruce sapwood at controlled temperatures and humidities for months and recorded when mold appeared and how fast it spread. Three findings from that work drive the model.

Humidity is the trigger

Mold needs a relative humidity of about 80% or more at the surface. Below that, spores stay dormant whatever the temperature. In the published model the critical humidity rises toward 100% as it gets close to freezing.

Temperature sets the pace

Growth is possible between about 0 °C and 50 °C (32 °F and 122 °F). Inside that window, warmer air makes mold grow faster; near freezing it is very slow.

Time decides the outcome

A humid hour does no harm. Mold needs a sustained period of high humidity before growth starts, and dry periods slow it down and reverse part of it. That is why the index is cumulative: it remembers what conditions have been, not only what they are now.

The 0–6 scale behind the percentage

Viitanen's model scores mold from 0 to 6 by what an inspector would see on the surface. LoggerFlex divides that score by 6 and shows it as a percentage, so 3 on the scale is 50% and 6 is 100%.

ScaleMold IndexWhat it meant in the VTT studies
00%No growth
117%Some growth, visible only under a microscope
233%Moderate growth under the microscope, covering more than 10% of the surface
350%First growth visible to the eye
467%Visible growth covering more than 10% of the surface
583%Visible growth covering more than 50% of the surface
6100%Heavy growth covering the whole surface

How your EDGE device calculates it

The device runs the calculation itself on every reading (every 1 to 30 minutes, as you set it), using its own temperature and humidity sensor. Each reading falls into one of three cases.

  1. 1Dry or out-of-range reading. If humidity is below 80%, or the temperature is below 0 °C or above 50 °C, the index falls by 0.1 on the 0–6 scale per day (about 1.7% per day), and any incubation time built up so far is reset to zero.
  2. 2Incubation. While humidity stays at 80% or more inside the temperature window, the device counts the uninterrupted time. The index holds where it is until that time reaches the incubation period: about 100 days at exactly 80% humidity, falling to about 1 day at 100% humidity and 50 °C. The period is worked out again on every reading, so it shortens as conditions get wetter and warmer.
  3. 3Growth. Once incubation is complete, the index climbs on every humid reading, faster the warmer and wetter it is, up to 100%. It keeps climbing until a dry reading starts the decline.

Examples from the device model

Constant conditionsIncubationThen 0% to 83%
4 °C (39 °F), 90% RH20 daysabout 13 hours
10 °C (50 °F), 85% RH17 daysabout 80 minutes
20 °C (68 °F), 85% RH9 daysone or two readings
25 °C (77 °F), 95% RH2.6 daysone or two readings

Readings every 10 minutes. One dry reading resets the incubation count, so a space that dries out every day may never reach the growth phase.

Same science, tuned for early warning

The device uses the model's 0–6 scale, its 80% humidity threshold, its temperature window and an incubation period. Once incubation ends, though, its growth step is much faster than the published laboratory curve. In practice the index works as a timer for sustained high humidity: it tells you conditions have favoured mold long enough to act, rather than estimating how much of a surface is covered. Treat a high value as a reason to inspect and dry the space.

What the Mold Index Is (And Isn't)

It is NOT a mold detector

The Mold Index does not show whether you certainly have mold or not. Our sensors do not detect physical mold spores in the air or on surfaces.

It IS a cumulative risk indicator

It provides an indication of how favorable the environment is for mold growth. Because mold requires time to grow, the index is a cumulative number—not a momentary snapshot. It factors in prolonged exposure to specific temperature and humidity combinations.

How Our Devices Help You

Early Warning

By tracking cumulative environmental data, you receive alerts when conditions become dangerous, long before mold becomes visible.

Predictive Maintenance

Identify areas with chronic humidity issues or poor ventilation, allowing you to fix structural or HVAC problems proactively.

Damage Prevention

Protect valuable assets, from building materials to museum artifacts and agricultural yields, by maintaining a 0% mold index.

Scientific References

The LoggerFlex Mold Index utilizes established empirical models for predicting mold growth on wooden and other building materials under fluctuating temperature and humidity conditions.

  • Hukka, A. & Viitanen, H. (1999). A mathematical model of mould growth on wooden material. Wood Science and Technology, 33(6), 475-485.
  • Viitanen, H. & Ritschkoff, A.-C. (1991). Mould growth in pine and spruce sapwood in relation to air humidity and temperature. Swedish University of Agricultural Sciences, Department of Forest Products, Report 221.
  • Ojanen, T., Viitanen, H., Peuhkuri, R., Lähdesmäki, K., Vinha, J. & Salminen, K. (2010). Mold growth modeling of building structures using sensitivity classes of materials. Thermal Performance of the Exterior Envelopes of Whole Buildings XI, ASHRAE.